Este producto ya no cuenta con el respaldo activo del desarrollo (Fin del soporte de desarrollo) y no se proporcionarn ms actualizaciones de software. Fin del soporte de desarrollo. MegaRAID Storage Manager Application for Windows (17.05.01.02) - Lenovo Support BO.
Megaraid Storage Manager Driver File Naming8-76 Management Software and Tools Version17.05.00.02OSLatest MegaRAID Storage Manager(MSM) MegaRAID Storage Manager Application Supported controllers: Onboard LSI 1064 SAS controller Onboard LSI 1064e SAS controller Onboard LSI 1068e SAS controller Onboard LSI 1078 SAS controller ServeRAID H1110 SAS/SATA Controller for IBM. New IBM xSeries firmware and device driver file naming convention Change history. Battery Backup Unit and array going offlineDownload Description. CAPABILITIES and FEATURES Storage controller Mezzanine Cards Cisco UCSC RAID. View online or download Cisco UCS C24 Installation And Service Manual.) Find the programs for your controller - example 9260-8i BBU for 3ware and MegaRAID have an 8Mhz CPU and if they fail, the data in cache stops moving making the array appear to be offline. Information Enclosure s Firmware download in progress.LSI MegaRaid controllers are available in various configurations.See The RAID array can be set up via the Adapter BIOS on boot.Save the Adapter configuration to a setarch x86_64 -uname-2.6 /opt/MegaRAID/MegaCli/MegaCli64 -help| grep CfgSaveMegaCli -CfgSave -f filename setarch x86_64 -uname-2.6 /opt/MegaRAID/MegaCli/MegaCli64 -CfgSave -f /admhome/cscf-adm/MegaRaidAdapterConfiguration -a0Battery Backup Unit and array going offline (This can be done by using the rpm-force command to install the rpm file directly, which is not recommended, instead of using the install.sh file.)The MegaRAID Storage Manager software enables you to configure the controllers, drives, battery. This message indicates that you have in stalled more than one copy of Dell SAS RAID Storage Manager.gdebi lib-utils2_1.00-9_all.deb megaraid-storage-manager_17.05.00-3_all.deb tar xf gunzip 17.05.00.02_Linux-64_MSM* MegaCLI, Storage Manager and StorCLI into directories with the same name Epson scan app for mac) Driver * tar xzf MR_LINUX_DRIVER_7.7-07.707.03.00-1.tgz MegaCli -adpfwflash -f mr2108fw.rom -a0 export PATH=$PATH:/opt/MegaRAID/MegaCli:/opt/MegaRAID/storcli Insert into PATH: /opt/MegaRAID/MegaCli:/opt/MegaRAID/storcli: * Add to current login shell ) Add MegaCLI and StorCLI utils to search path vi /etc/environment *update-rc.d vivaldiframeworkd defaults ![]() The architecture must be specified in the Storage Manager$ sudo setarch x86_64 -uname-2.6 /opt/MegaRAID/MegaCli/MegaCli64 -adpCountSudo setarch x86_64 -uname-2.6 /opt/MegaRAID/MegaCli/MegaCli64 -helpGetting all information about the AdapterSetarch x86_64 -uname-2.6 /opt/MegaRAID/MegaCli/MegaCli64 -CfgDsply -aALLSilencing an Storage Manager$ sudo setarch x86_64 -uname-2.6 /opt/MegaRAID/MegaCli/MegaCli64 -AdpSetProp AlarmSilence -aALLAdapter 0: Set alarm to Silenced success.Finding a faulty drive may be easy on some systems. /MegaCli64 -AdpAllinfo -aALLThe problem lies in the architecture. /MegaCli64 -CfgDsply -a0User specified controller is not present.Exit Code. Provides us with a whole bunch of command optionsNormally one would execute the CLI via the current path. Hence, it can't be determined that it was previously the hot spare.In the "pdlist" command "Slot" will display drive bay number. Use the next command to view the drive:Setarch x86_64 -uname-2.6 /opt/MegaRAID/MegaCli/MegaCli64 -PdInfo -PhysDrv -a0 #Where E is the enclosure ID and S is the drive bay slot.If the hot spare is built into the array it will report as "Online, Spun Up". If a "hot spare" drive is faulty the array won't be degraded.The next command asks for "ldinfo" Logical Drive Info, "lall" All Logical devices, "a0" for Adapter Storage Manager$ sudo setarch x86_64 -uname-2.6 /opt/MegaRAID/MegaCli/MegaCli64 -ldinfo -lall -a0RAID Level : Primary-6, Secondary-0, RAID Level Qualifier-3Default Cache Policy: WriteBack, ReadAhead, Direct, No Write Cache if Bad BBUCurrent Cache Policy: WriteBack, ReadAhead, Direct, No Write Cache if Bad BBUDefault Power Savings Policy: Controller DefinedLD has drives that support T10 power conditions: NoLD's IO profile supports MAX power savings with cached writes: YesTo get a log of the setarch x86_64 -uname-2.6 /opt/MegaRAID/MegaCli/MegaCli64 -adpeventlog -getevents -f lsi-events.log -a0 -nolog-rw-r-r- 1 root root 9764271 Feb 26 16:08 lsi-events.log-rw-r-r- 1 root root 1226454 Feb 26 16:06 MegaSAS.logLog entry pertaining to the faulty less lsi-events.log.searched for "Jan 30" in this long file containing log data from "Oct 3"Event Description: Unexpected sense: PD 0c(e0x21/s3) Path 50030480015b134f, CDB: 28 00 86 8c 04 80 00 00 80 00, Sense: 3/11/000028 0000 0086 008c 0004 0080 0000 0000 0080 0000 0000 0000 0000 0000 0000 0000 Sense Length: 18To get information about all the drives in the array use the pdlist option on the array controller Storage Manager$ sudo setarch x86_64 -uname-2.6 /opt/MegaRAID/MegaCli/MegaCli64 -pdlist -a0Inquiry displays the drive's serial number.Firmware states are either "Failed", "Online, Spun Up", "Online, Spun Down", "Unconfigured(bad)", "Unconfigured(good), Spun down", "Hotspare, Spun down", "Hotspare, Spun up" or "not Online".If a hot spare has been built into the array to compensate for the failed drive, then the above command may not show the failed drive as failed. The RAID adapter may also sound an alarm.To get information about the entire RAID Storage Manager$ sudo setarch x86_64 -uname-2.6 /opt/MegaRAID/MegaCli/MegaCli64 -adpallinfo -a0One interesting piece of information resulting from the above command:The logical drive information will not give a specific drive, but will report whether the array is degraded.
0 Comments
Leave a Reply. |
AuthorBrian ArchivesCategories |